Non Reflective Films are normal tinted films which primarily cuts the heat. Super shrink & Anti-static qualities helps in easy installation.
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 6% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 45% |
| Solar Energy Reflectance | 7% |
| Solar Energy Absorbance | 48% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 93% |
| Shading Coefficient | 0.67 |
| Emissivity | 0.85 |
| U Factor (BTU /HR./SQ.FT.) | 1.12 |
| Total Solar Energy Rejection | 42% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 21% |
| Visible Light Reflectance | 5% |
| Solar Energy Transmittance | 45% |
| Solar Energy Reflectance | 6% |
| Solar Energy Absorbance | 49% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 77% |
| Shading Coefficient | 0.68 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.15 |
| Total Solar Energy Rejection | 42% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 35% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 53% |
| Solar Energy Reflectance | 7% |
| Solar Energy Absorbance | 40% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 62% |
| Shading Coefficient | 0.75 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.12 |
| Total Solar Energy Rejection | 36% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 51% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 60% |
| Solar Energy Reflectance | 7% |
| Solar Energy Absorbance | 33% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 44% |
| Shading Coefficient | 0.80 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.14 |
| Total Solar Energy Rejection | 31% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 70% |
| Visible Light Reflectance | 7% |
| Solar Energy Transmittance | 70% |
| Solar Energy Reflectance | 9% |
| Solar Energy Absorbance | 21% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 23% |
| Shading Coefficient | 0.87 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.13 |
| Total Solar Energy Rejection | 24% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 4% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 41% |
| Solar Energy Reflectance | 6% |
| Solar Energy Absorbance | 53% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 96% |
| Shading Coefficient | 0.64 |
| Emissivity | 0.85 |
| U Factor (BTU /HR./SQ.FT.) | 1.12 |
| Total Solar Energy Rejection | 44% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 22% |
| Visible Light Reflectance | 5% |
| Solar Energy Transmittance | 49% |
| Solar Energy Reflectance | 6% |
| Solar Energy Absorbance | 45% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 76% |
| Shading Coefficient | 0.72 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.13 |
| Total Solar Energy Rejection | 38% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 35% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 54% |
| Solar Energy Reflectance | 7% |
| Solar Energy Absorbance | 39% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 62% |
| Shading Coefficient | 0.76 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.14 |
| Total Solar Energy Rejection | 35% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 50% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 58% |
| Solar Energy Reflectance | 7% |
| Solar Energy Absorbance | 35% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 45% |
| Shading Coefficient | 0.78 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.14 |
| Total Solar Energy Rejection | 32% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 70% |
| Visible Light Reflectance | 7% |
| Solar Energy Transmittance | 70% |
| Solar Energy Reflectance | 9% |
| Solar Energy Absorbance | 21% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 23% |
| Shading Coefficient | 0.87 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.13 |
| Total Solar Energy Rejection | 24% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 70% |
| Visible Light Reflectance | 7% |
| Solar Energy Transmittance | 70% |
| Solar Energy Reflectance | 9% |
| Solar Energy Absorbance | 21% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 23% |
| Shading Coefficient | 0.87 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.13 |
| Total Solar Energy Rejection | 24% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 17% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 46% |
| Solar Energy Reflectance | 6% |
| Solar Energy Absorbance | 48% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 81% |
| Shading Coefficient | 0.68 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.13 |
| Total Solar Energy Rejection | 41% |
| Properties | Unit |
| Thickness | 1 Mil |
| Visible Light Transmittance | 30% |
| Visible Light Reflectance | 6% |
| Solar Energy Transmittance | 48% |
| Solar Energy Reflectance | 7% |
| Solar Energy Absorbance | 45% |
| Ultra Violet Transmittance | < 1% |
| Glare Reduction | 67% |
| Shading Coefficient | 0.71 |
| Emissivity | 0.86 |
| U Factor (BTU /HR./SQ.FT.) | 1.14 |
| Total Solar Energy Rejection | 39% |