| Sr.No | Properties | Unit |
|---|---|---|
| 1 | Thickness | 2 Mil |
| 2 | Visible Light Transmittance | 26% |
| 3 | Visible Light Reflectance | 17% |
| 4 | Solar Energy Transmittance | 14% |
| 5 | Solar Energy Reflectance | 15% |
| 6 | Solar Energy Absorbance | 71% |
| 7 | Ultra Violet Transmittance | < 1% |
| 8 | Glare Reduction | 71% |
| 9 | Shading Coefficient | 0.40 |
| 10 | Emissivity | 0.83 |
| 11 | U Factor (BTU /HR./SQ.FT.) | 1.10 |
| 12 | Total Solar Energy Rejection | 65% |
| 13 | NIR Blocking at 1025 NM | 94% |
| Sr.No | Properties | Unit |
|---|---|---|
| 1 | Thickness | 2 Mil |
| 2 | Visible Light Transmittance | 53% |
| 3 | Visible Light Reflectance | 7% |
| 4 | Solar Energy Transmittance | 33% |
| 5 | Solar Energy Reflectance | 5% |
| 6 | Solar Energy Absorbance | 62% |
| 7 | Ultra Violet Transmittance | < 1% |
| 8 | Glare Reduction | 42% |
| 9 | Shading Coefficient | 0.59 |
| 10 | Emissivity | 0.88 |
| 11 | U Factor (BTU /HR./SQ.FT.) | 1.12 |
| 12 | Total Solar Energy Rejection | 49% |
| 13 | NIR Blocking at 1025 NM | 88% |
| Sr.No | Properties | Unit |
|---|---|---|
| 1 | Thickness | 1.5 Mil |
| 2 | Visible Light Transmittance | 69% |
| 3 | Visible Light Reflectance | 7% |
| 4 | Solar Energy Transmittance | 46% |
| 5 | Solar Energy Reflectance | 5% |
| 6 | Solar Energy Absorbance | 49% |
| 7 | Ultra Violet Transmittance | < 1% |
| 8 | Glare Reduction | 24% |
| 9 | Shading Coefficient | 0.70 |
| 10 | Emissivity | 0.89 |
| 11 | U Factor (BTU /HR./SQ.FT.) | 1.13 |
| 12 | Total Solar Energy Rejection | 40% |
| 13 | NIR Blocking at 1025 NM | 82% |
| Sr.No | Properties | Unit |
|---|---|---|
| 1 | Thickness | 2 Mil |
| 2 | Visible Light Transmittance | 69% |
| 3 | Visible Light Reflectance | 8% |
| 4 | Solar Energy Transmittance | 38% |
| 5 | Solar Energy Reflectance | 7% |
| 6 | Solar Energy Absorbance | 55% |
| 7 | Ultra Violet Transmittance | < 1% |
| 8 | Glare Reduction | 24% |
| 9 | Shading Coefficient | 0.61 |
| 10 | Emissivity | - |
| 11 | U Factor (BTU /HR./SQ.FT.) | - |
| 12 | Total Solar Energy Rejection | 49% |
| 13 | NIR Blocking at 1025 NM | 90% |
| Sr.No | Properties | Unit |
|---|---|---|
| 1 | Thickness | 2 Mil |
| 2 | Visible Light Transmittance | 79% |
| 3 | Visible Light Reflectance | 9% |
| 4 | Solar Energy Transmittance | 47% |
| 5 | Solar Energy Reflectance | 7% |
| 6 | Solar Energy Absorbance | 46% |
| 7 | Ultra Violet Transmittance | < 1% |
| 8 | Glare Reduction | 13% |
| 9 | Shading Coefficient | 0.69 |
| 10 | Emissivity | - |
| 11 | U Factor (BTU /HR./SQ.FT.) | - |
| 12 | Total Solar Energy Rejection | 42% |
| 13 | NIR Blocking at 1025 NM | 76% |